Current oven required 40 amps. Informations sur votre appareil et sur votre connexion Internet, y compris votre adresse IP, Navigation et recherche lors de l’utilisation des sites Web et applications Verizon Media. Double-Pole Circuit Breaker has a tin-plated copper stab that creates permanent and corrosion-resistant connection. If he has a different oven then there is no way we can comment on that without the new model number's specifications. Should be fused separately. I think all I have to do is swap out the 50 amp dual pole breaker and replace it with a 40 amp dual pole breaker and I should be good to go. Dave’s Reply: Can I change a ceiling fan switch and wiring from one wire to two. The 10/3 romex will allow up to 30 amps to flow through it safely. 1 Pole 30 Amp Thick Series by Connecticut Electric. Date published: 2020-09-01. Ferguson Bath, Kitchen & Lighting gallery. FREE Delivery on your first order of items shipped by Amazon . That's incorrect. This is what you have. Qualified Orders Over $49 Ship Free. Homeowner put new 40 amp double oven in and was wired to a #10 and 30 amp breaker. Generally, the appliance takes up close to 12 amps and requires a dedicated 20-amp breaker setup. When I look at my electrical panel, I see it is hooked up to two 30-amp breakers which someone told me would be called "piggybacked" and can be thought of as 60 amps. Going with a 40 amp breaker opens a new can of worms. Exposed wiring in attic previously connected to ceiling fan. I know you want a nice definitive number, sadly there isn’t one. 4.4 out of 5 stars 80. The wire is hooked up to a 30 amp breaker in the panel. Total load rating of 4.4kw. 41 $21.74 $21.74. Can you give me some advice about this matter? True that they will both require 60 amps total but the ovens should not be connected to a single 60 amp circuit. 1 product rating. The double oven at the link he posted specifies: 240v=6.9 kv; 240v= 30 amps. 10 ground wire in conduit. The unique Stab-lok breaker design of only a 1/2 thick per pole, allows for the reduction of the size and weight of the loadcentre. If the oven doesn't work, check voltage at the source and at the JB that is wired to. CDN$ 34.99 CDN$ 34. The utility wires serving your home are probably aluminum. we have an electrical stove that is hooked up to a 30 amp breaker (that's what it is supposed to use), the stove being the only thing on that circuit. Mike, Home Appliance Technician. if i remember right my oven called for a 40 amp breaker,which takes a # 8. i was runing about 35' so i went to a #6. i know what your talking about but if my insp. She ended up going with a true commercial range (not just professional style). I will be replacing my gas double oven with an electric one, one like a Bosch HBM13B150B. Find the right double wall oven for your kitchen in 27" or 30" sizes. I'm guessing that the oven cord will fit the existing 50 amp outlet-I didn't see any 40 amp outlets at the store, only 30 and 50 amp ones. An oven seldom functions smoothly on a shared electric circuit. $24.98 $22.99 New & In Stock. I am replacing an existing electric double wall oven. a 40 amp breaker would be marked "40". Really depends what type of oven you have. I often take pans directly from burners to oven and back, along with hot oven dishes out to cool on the burners tops. 4.6 out of 5 stars 124. If you only have room for a double combo, I would recommend a convection/microwave over a conventional (or conventional with convection) oven. The second time around, this interior designer gets her kitchen just right, With all that extra space for slicing and dicing, dual islands make even unsavory kitchen tasks palatable, If you love homemade pizza and are (ahem) rolling in dough, a wood-burning oven may be just the right kitchen investment, Sleek materials, walls of glass and double-height rooms create a glamorous, light-filled home in north London. Note that you (ie. 5. These recent posts got me back to researching. What you have now is a 30 amp, 240v circuit. Re: 40 amp range, 30 amp circut [Re: jdevlin] #489200 09/28/08 01:01 AM 09/28/08 01:01 AM: Joined: Jun 2003 Posts: 205 Des Moines, Iowa. I knew there had to be a reason that it was different than the other breakers and I really wanted to double "something". Some manufacturers, such as Neff, have recognised the lack of features in cookers rated under 3kW, and are now making models with more advanced multi-features and so on which can still be plugged into a 13-amp plug. I am planing to get new 40amp double oven. Models rated at 7.2 kW and below at 240 volts (5.4 kW and below at 208 volts) require a separate 30-amp circuit. The 2nd row from the bottom shows amp ratings of those ovens. That probably means running new wire for the new double oven. $9.00. This breaker replaces another GE 30 amp double pole circuit that was installed at residence six years ago. Get it by Tomorrow, Nov 13. See all 8 - All listings for this product. seneca, Nov 15, 2017 #5. It may take a while before it trips, and that's ok. I guess I thought this made sense since my existing oven called for 40 amps. So why isn't the existing 30 amp circuit good enough for the new oven, if the wall oven runs on 30 amps? Q230 30-Amp Double Pole Type QP Circuit Breaker. It looks like both may be rated for 20 amp breaker (each on its own dedicated circuit). An electrician would install a 30-amp 240-volt circuit to serve such a water heater. Question: My old consumer unit has 30 amp fuses. This GE Q-Line 30 Amp 1 in. I hope that this information helps. The double pole Double-Pole Circuit The GE Q-Line 30 Amp 2 in. I was astounded at the price. Découvrez comment nous utilisons vos informations dans notre Politique relative à la vie privée et notre Politique relative aux cookies. larry. The attached screw creates a stable calibration for optimum performance. Connect directly to the circuit breaker box (or fused disconnect) through flexible, armored or nonmetallic, sheathed copper cable (with grounding wire). Category: Appliance. When I look at my electrical panel, I see it is hooked up to two 30-amp breakers which someone told me would be called "piggybacked" and can be thought of as 60 amps. My house was built in Michigan in 2004/2005. I often use one oven to warms plates or keep warm dishes that I have cooked on burners. In this article, the first in a series exploring permit processes and requirements, learn why and when you might need one, Have all the options for ovens, with or without cooktops and drawers, left you steamed? My question is will my new oven work properly with this double breaker thing (2 X 30 = 60 amps). I know it needs a box to install a light, but what shape? Is the aluminum wire ok? Q230 30-Amp Double Pole Type QP Circuit Breaker. The existing outlet is 240/208 50 amps. Satisfied Customers: 17,630. I recently purchase a GE 30 inch single wall oven and 30 inch cooktop. But a regular double will be good on a 40amp dedicated circuit… Vous pouvez modifier vos choix à tout moment dans vos paramètres de vie privée. UBIF30N- Federal Pacific Electric Stab-Lok NA130 Replacement. 20A would be awful low for an oven. So the top is gas and the oven is electric, am I deciphering that right? My recollection was that there had to be 18" between the range and the closest surface. Or if he HAS the new oven, then the rating plate will give the proper amperage. 1 users rated this 5 out of 5 stars 1. The only problem is that these aren't built for installation next to cabinetry. I'm planning to install an electric oven (240V) and a microwave oven (120V). My installer was here to scope out the project and said that I had a 6 AWG ALUMINUM wire so I would be fine just switching out the 30A breaker for 50A. FREE Shipping. Maybe if you would be kind enough to elaborate on why the oven was done this way - two breakers attached to one another - I would be better able to explain this to the oven installers to see if I need to have an electrician here first to switch the two 30s for a 50. Electrical requirements 4-wire ground, 240 VAC, 30 amp electrical connection for single ovens/ 50 amp for double ovens. #10 just won't fly. Also, how did the old oven needing 40 amps work on 30 amps? 4.8 out of 5 stars 1,186. Homeowner had electrician come out and electrician said since kitchen was upstairs, to difficult to run new wire and he should just put in a 35 amp breaker and all would be good. Models rated at 7.2 kW and below at 240 volts (5.4 kW and below at 208 volts) require a separate 30-amp circuit. your electrician) can't just switch the 30A double breaker for a 50A double breaker. Unit is equipped with No. Shop Siemens QP 30-Amp 2-Pole Standard Trip Plug-On Neutral Circuit Breaker in the Circuit Breakers department at Lowe's.com. 30-50A is more typical depending on size, etc. A standard kitchen range with four burners and an oven could draw 30, 40 or 50 amps. I would imagine that the oven has a piece of 1.5mm 3 core flex, this will not be protected by the 30A MCB, your solution is either fit a 16A breaker in the board or install a 16A breaker in an enclosure behind the oven or in a cupboard adjacent to it. Q-Line 30 Amp 2 in. I was talking to the "technical support" person at Wolf and described my panel to them. 3. If it's wired correctly and the connections are good, the problem will be in the oven. 89 $21.74 $21.74. A circuit breaker is recommended. This gives you the option of using the convection/microwave like a conventional oven, or as a microwave. yes, you can plug your oven into a 30 amp circuit to test it. It was hooked up to 10/3 copper wire on a 30 amp breaker. With proper connections, aluminum wiring is perfectly safe. Oven offers 30 amps and microwave offers 950 watts of power Kenmore 49423 30" Electric Self-Clean Single Wall Oven... $774.00 Originally: $1,719.99 (List Price) Also, the Wolf oven instructions to use 10 AWG doesn't match up with what I have read. The flex will have short circuit protection from the 30 amp mcb and it's a fixed load so there's no chance of overload so as UP said, leave it as it is. They get three (3) stars for being inexpensive and easy to find. Electrical requirements 4-wire ground, 240 VAC, 30 amp electrical connection for single ovens/ 50 amp for double ovens. 4. If you want a double oven, but don’t have the wall space, this gas range is a great option. Aluminum wire, in and of itself, is no cause for alarm. Doing a kitchen remodel and the new oven calls out for a 240/208 40 amp outlet. So far so normal. For example, if you have a fairly small 800-watt microwave oven, the electrician will normally install a 20-amp circuit even though a 15-amp circuit can easily handle this appliance. A single 30A breaker would supply 30A at 120V.A double 30A breaker would supply 30A at 240V. Siemens plug in circuit breakers are intended for use in Siemens EQ, Siemens ultimate, ire, and Gould load centers or meter combinations. Knowing the requirements for an electric range and oven allows the proper electrical service to be installed during the construction process. Double-Pole Circuit Breaker The GE Q-Line 30 Amp 2 in. Electric stoves with an oven generally require a 50A circuit. If cost and counter space are not an issue then how you cook on a regular basis is the key factor. 4.7 out of 5 stars 1,216. Greg,Thanks. Quantity Quantity. F. figaro OP enthusiast figaro OP enthusiast. (House and oven are seven years old.). If your budget allows, GE's has a version with Aadvantium which really cooks fast, although it's pretty spendy. The industry's best value in circuit protection in a 1 inch wide industry-standard format for one-pole circuit breakers. If your oven installers have a licensed electrician, that's fine, but don't let just anybody mess with your electrical system.Most likely, the work will need a permit and an inspection. Other options New and used from $16.61. Other options New and used from CDN$ 17.14. Never used both ovens at the same time so never had a problem. A 40 amp circuit is limited to 32 amps. Ovens in another location even if a step away would drive me crazy. However, I feel like this may be too small. Look for the FLA, or "full load amps". Most electricians will put a regular double on a 50 amp also because if both ovens are on the unit will draw close to 40 amps. Easy Returns. The original oven was an older Lady Kenmore double oven, and it used a dual-30A breaker. CDN$19.94. when all 4 heaters on stove are turned on, and oven turned on, the breaker trips after only a 3-4 minutes. The circuit breaker current rating must match the rating on this label. Details on new oven below. Remember the new range top is gas. SIEMENS Q21530CT 30 Double Two 15-Amp Single Pole Circuit Breaker, As Shown in The Image. your double oven requires a 40 amp circuit because that's the Highest current it's ever supposed to draw. Re: 40 amp range, 30 amp circut [ … Total amps: 37 amps.Supply wire minimum size: L1, L2 and ground-10 AWG. Yahoo fait partie de Verizon Media. The new dryers need a 30 amp plug, currently has 50 amp plug. If you'll have an open wall, it could work. This is an old Federal Pacific breaker panel, which doesn't have a very good reputation. The original #6 would also indicate a larger original Amp installation. Wire gauge for Double oven hook up [ 7 Answers ] I am replacing old oven with double oven, current oven is on a 20 amp breaker, old wiring can not make out the gauge. It looks like both may be rated for 20 amp breaker (each on its own dedicated circuit). Other options New and used from $6.59. It’s unlikely that a 13-amp plug will be sufficient for a model that has a hob as well as an oven. For a kitchen remodel I am replacing a range which is wired with a 50 Amp circuit an 6 AWG AL wire with a cooktop calling for a 30 Amp circuit and 20 Amp oven which will be installed below the cooktop. A new cable will most likely have to be run to your oven location. 2. Told him he needed #8 and 40 amp breaker. If the flex feeding the oven is 1.5mm2 then it is usual to fit a 13A fused plug or wire to a 13A fused spur to protect the flex , not the oven. Then again I am mostly crazy anyway. Double check the AMPs required for the stove. http://www.amazon.com/36-inch-Commercial-Range-American/dp/B001S2Z8WO. If a double convection oven then the circuit really needs to be 50 amp. It's a code violation not to install the range according to the manufacturers directions. A circuit breaker is recommended. Buy them new or reconditioned online or in … The circuit feeds a cooker outlet which feeds an oven and a hob. I have a question regarding putting a 20 amp outlet on a 30 amp circuit. Q230 - Siemens 30 Amp Double Pole Circuit Breaker by Siemens / ITE. Homeowners often take for granted the continued operation of the home's electrically powered appliances. The cooker circuit is 6mm T&E via type B 30A MCB. $10.41 $ 10. Shop Online. That's where I got the information that my two 30-amp breakers were like a 60-amp one and would be ok. A friend built a house a few years ago and had the same issue. Fused spur reqd for oven on 1.5mm flex? In fact, I have done trouble shooting FOR electricians. CDN$ 61.84 CDN$ 61. That includes thicker wire between the breaker and stove to prevent an electrical fire. I’m … 84. If a double convection oven then the circuit really needs to be 50 amp. The circuit breaker current rating must match the rating on this label. But a large commercial unit, or one with features like a convection oven or quick-heat burners, draw 50 to 60 amps. The install sounds fishy. Get it as soon as Mon, Nov 16. Pour autoriser Verizon Media et nos partenaires à traiter vos données personnelles, sélectionnez 'J'accepte' ou 'Gérer les paramètres' pour obtenir plus d’informations et pour gérer vos choix. T Tocas 30 Amp Surface-Mount Circuit Breakers with Manual Reset for Auto Boat Marine, 12V- 48V DC, Waterproof. would see 10 on a 40 amp, i'd be red tag! WOLF L SERIES ELECTRIC DOUBLE OVEN (DO30)Power supply: 240/208 V AC, 60 Hz with 50 amp service.Maximum connected load: 8.9 kW.Total amps: 37 amps.Supply wire minimum size: L1, L2 and ground-10 AWG. I have this combination myself and absolutely LOVE it! I replaced the plug but noticed it was ran to a double pull 40 breaker, is Add to cart Q230 - Siemens 2 Pole 30 Amp Breaker. It's a code violation not to install the range according to the manufacturers directions. The attached screw stabilizes the calibration for optimum performance. I have just bought a double oven which requires hard-wiring 45 amp fuse. Siemens QP breakers provide easy plug-in connections in … The oven is not being protected by the 32A mcb, the circuit cable is. Your new oven calls for a 50 amp, 240v circuit. 94. Browse our selection of high-quality, long lasting double wall convection ovens. Other options New and used from $4.52. BV005087. if it works fine you may not have to upgrade the circuit at all. My microwave is upper and directly next to the range. I also prefer to have a minimum of 24" of counter on either side of the range to allow pot handles and other items to be right next to the range. ... a double-oven version. My installer said I was lucky, since a new wire would cost over $500 and even more for copper. Q230 30-Amp Double Pole Type QP Circuit Breaker. But a regular double will be good on a 40amp dedicated circuit. But I doubt it. How to hide or camouflage outlets in a quartz backsplash?? FREE Shipping. This allows get all the cooking done standing in one place. A double oven requires two 30 amp circuits each controlled a by double pole 30 amp breaker. Unlike a double-pole breaker, which serves a single 240-volt circuit, a cheater serves two 120-volt circuits; it cannot be used to supply 240 volts to a single circuit. Thanks so much for the quick reply. The pigtailed #12's coming off of the #6 wouldn't cut it for over 20A. Double Pole 30 Amp Homeline Plug-On Circuit Breaker Canadian Homeline Circuit Breakers provide the high level of protection you expect from Schneider Electric. It's a code violation to install a 40 amp recpetacle on the 30 amp circuit. 0 users rated this 4 out of 5 stars 0. These functions only operate if the appliance is connected to an adequate electrical service. It's a code violation to install a 40 amp recpetacle on the 30 amp circuit. If you're the luckiest girl in the world, the cable will be the correct size already. Perhaps the old wiring was for a cooktop unit or separate oven. As my old electric freestanding double oven cooker has given up I want to replace it with a built in job and induction hob. Siemens plug in circuit breakers are intended for use in Siemens EQ, Siemens ultimate, ire, and Gould load centers or meter combinations. I'm linking a sample from amazon that isn't the same model but is the same idea. Should be fused separately. I bought a double oven from craigslist the other day, but my existing wall oven wiring (4 wires) is running from a breaker switch rated at 30 amps. It just looks like two breaker switches tied together so to reset, they both move together. Received from Alan a Homeowner in Sheffield UK. A 30 amp circuit cannot supply a single load of more than 24 amps. I have done almost as much electrical work as plumbing. The oven being 3kW (or in this case 3.6kW) is a fixed load so will only draw its maximum current with full load. I'm planning to install an electric oven (240V) and a microwave oven … Do I need to - Answered by a verified Electrician. Given that the installation instructions for your oven require the use of a dedicated circuit, as follows: Models rated from 7.3 to 9.6 kW at 240 volts (5.5 to 7.2 kW at 208 volts) require a separate 40-amp circuit. double oven cooker and induction hob power supply. Hob is to remain as Gas My gas oven electrical circuit is fed by a 13amp fused plug into a single switched socked fed by 2.5mm cable on a ring main. 0 users rated this 3 out of 5 stars 0. Only 5 left in stock - order soon. A different type of doubled-up breaker is a "quad breaker," which serves two 240-volt circuits but is the same width as a standard double-pole breaker. I understand your response and that either an electrician or the oven installer will need to both run a new cable and replace the breaker. FREE Shipping on orders over $25 shipped by Amazon . I am not a fan of GE circuit breakers and would not have selected them when the house was built. 4.7 out of 5 stars 31. The wiring and breakers for these circuits are required to be designed at 125% of the continuous load and 100% of a non-continuous load. Double-Pole Circuit Breaker has a dedicated calibration screw which is cemented to prevent shifting. Get it as soon as Tue, Dec 1. This breaker will work only in Federal Pioneer Stab-lok branded residential panels. Electrical Question from Alan about Wiring a Double Oven. There are some Kenmore double ovens with a 30 amp rating. Q230 30-Amp Double Pole Type QP Circuit Breaker 4.8 out of 5 stars 2,744. 4.8 out of 5 stars 2,607. Unit is equipped with No. It is a single oven rated at 16a that has replaced a rubbish Beko double oven that gave constant issues. Check out American Freight for discount prices. The calibration screw is cemented to prevent shifting and provides a stable connection. The double wall oven needs a 40 amp circuit. Looking for the leading 30 amp electric oven on the market? I want to hook up a 24 inch electric stove/range to 10 gauge 3 copper wire with ground wire. 4.7 out of 5 stars 1,272. After investigating, I am worried about the wire being aluminum instead of copper. Building Permits: When a Permit Is Required and When It's Not, Find the Right Oven Arrangement for Your Kitchen, Double-Sided Fireplaces Multiply Design Options, Double Take: 'Floating' Wine Bottles Rack Up Style Points, Double-Duty Savvy: 10 Supersmart Laundry Room Combos, Kitchen of the Week: Double Trouble and a Happy Ending, Kitchen Luxuries: The Wood-Fired Pizza Oven, Houzz Tour: The Height of Luxury in a Modern Glass House, Ferguson Bath, Kitchen & Lighting Gallery. What you have now is a 30 amp, 240v circuit. Save on GE circuit breakers. 28. There are special requirements to prevent oxidation at splices and connections, however, such as using approved wire nuts when connecting aluminum to copper, and using anti-oxidant paste, which looks like black goop. 40-amp circuit. Normally two separate runs of #10/3 cable serve the double oven. that would be with both ovens heating and all the lights, timers, and any other bells and whistles operating. The ovens beginning in the third column all are rated at 30 amps. $96.00 $ 96. (with... Oven and Hob - advice on if a double oven and induction hob can be serviced by one circuit. 10 ground wire in conduit. When I look at my electrical panel, I see it is hooked up to two 30-amp breakers which someone told me would be called "piggybacked" and can be thought of as 60 amps. HeavyDuty | Oct 26, 2004 06:27am | #4. The double pole 40-amp circuit. It depends on whether you have space for a double wall oven - if so - that's preferable. Most electricians will slightly oversize the dedicated circuit size to allow for future changes. $30.28 $ 30. I just bought a home and needed to buy a new washer and dryer. I'm renovating a rental unit and removed a 3 in one appliance (bar fridge/2 stove elements/sink). The oven manual requires a 40 amp circuit breaker. is that ok to conect new oven to previous outlet that its run 10-4 wire with 30amp double circute breaker in panel box. Many homes have 30-A or 50-A breakers dedicated to larger appliances such as water heaters, baseboard heaters, ovens, stoves, and heavy-duty power tools. There are exceptions to that, but I believe the exceptions apply to a few specific things, such as motors, that have a huge current draw at startup.One of the pros will have to comment about the oven's specification of 10 AWG supply wire on a 50 amp circuit for an oven with a possible 37 amp current flow. The new oven calls for 50 amps. CDN$ 19.94 CDN$ 19. A double oven would draw about twice that much. If I need to replace that breaker, then I really need to replace the whole panel. FREE Shipping on orders over $49. I'm replacing appliances in my kitchen, and there's currently a 30 amp, 240V, 3-wire + ground feed to the location where the oven is located, on a 30 amp, double pole breaker. FREE Shipping on orders over $25 shipped by Amazon. item 7 Westinghouse 30 amp 2 pole circuit breaker Cat# BR230 Eaton CH 120/240 VAC 7 - Westinghouse 30 amp 2 pole circuit breaker Cat# BR230 Eaton CH 120/240 VAC. That's incorrect. GE THQL2120GFT Plug-in Mount Type THQL Feeder Self-Test Ground Fault Circuit Interrupter 2-Pole 20 Amp 120/240 Volt AC. Professional style range and wall oven/microwave vs. professional cooktop with double wall ovens and microwave, Double oven range vs double ovens + cooktop, Double wall oven vs range + single oven under counter, microwave/single oven combo vs double wall oven. Other options New from CDN$ 38.68. American Freight & Sears Outlet have combined. A 30 amp circuit under a 31 amp load will not trip right away. So nice of you to help me out here.Amy. 3. Siemens Q24040CT2 Two 40-Amp Double Pole Circuit Breaker. do I need to change the wires to higher rated amp or can I change the cicutr breaker to 40 amp with same thikness wires. Maximum amp usage 23.3 amps—240 VAC 20.2 amps—208 VAC 46.7 amps—240 VAC 40.5 amps—208 VAC Oven interior width 25” (63.5 cm) Additional Comments: It seems a good site, helpful. An oven is a continuous load since it can pull its full rated power for an indeterminate time. But it doesn't sound right to me. 30 Amp circuit. This the fourth breaker that has gone bad. the stove is brand new. Nos partenaires et nous-mêmes stockerons et/ou utiliserons des informations concernant votre appareil, par l’intermédiaire de cookies et de technologies similaires, afin d’afficher des annonces et des contenus personnalisés, de mesurer les audiences et les contenus, d’obtenir des informations sur les audiences et à des fins de développement de produit. The circuit breaker for our oven is a dual switch 30 amp. I'm doing a periodic inspection report for a client. Models rated at 7.2 kW and below at 240 volts (5.4 kW and below at 208 volts) require a separate 30-amp circuit. The chart in the third image shows Kenmore double-oven models that have a 30 amp breaker requirement. Mike. I have a 48" five star range with small gas oven and large convection. Discussion in 'Electricians' Talk' started by live it up, Dec 18, 2008. live it up New Member. It should be marked somewhere with an amperage requirement, or you can use an amp meter to read the amperage drawn by the oven when it is on. But a large commercial unit, or one with features like a convection oven or quick-heat burners, draw 50 to 60 amps. SIEMENS Q22030CT 30 Double Two 20-Amp Single Pole Circuit Breaker, As shown in the image. I have a question regarding putting a 20 amp outlet on a 30 amp circuit. 5.0. This guide will help you simmer down, Experts serve up advice on caring for these kitchen appliances, which work extra hard during the holidays, Flames on two (or more) sides of a fireplace turn up the heat in interior designs, Look closely to spy the secret of this wine rack, concocted by a clever homeowner needing a design workaround, Throw some extra function in along with the fabric softener to spin your laundry room into mutitasking mode, Burst pipes result in back-to-back kitchen renovations. Don't do it. Shop Siemens QP 30-Amp 2-Pole Standard Trip Plug-On Neutral Circuit Breaker in the Circuit Breakers department at Lowe's.com. A licensed electrician is required to do the electrical work. Connect directly to the circuit breaker box (or fused disconnect) through flexible, armored or nonmetallic, sheathed copper cable (with grounding wire). Most electricians will put a regular double on a 50 amp also because if both ovens are on the unit will draw close to 40 amps. That probably means running new wire for the new double oven. Your new oven calls for a 50 amp, 240v circuit. Don't mean to hijack the thread but I have similar questions if you don't mind. Double Pole 30 Amp Stab-lok (NC) Plug-On Circuit Breaker Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. $9.89 $ 9. However, I feel like this may be too small. I'm replacing appliances in my kitchen, and there's currently a 30 amp, 240V, 3-wire + ground feed to the location where the oven is located, on a 30 amp, double pole breaker. I removed old cook top and wall over both of them were connected to one electrical supply with a double 40 amp each circuit breaker. I was hoping to reuse that one. I think i would feel safer running both on a 30 amp breaker (again each on its own). I recently purchase a GE 30 inch single wall oven and 30 inch cooktop. You won’t believe what can fit in just 30 inches of space: a five-burner gas range with up to 17000 BTUs, plus a half oven and a full-size oven that amount to 6.0 cubic feet of cooking space.